← Dashboard

Boiler — Columbia MPH-70

PLR

Steam Flow

Steam Temp

Efficiency

Fuel Input

Net Output

h_steam

h_return

Efficiency vs Part-Load Ratio
Columbia MPH-70 Nameplate Ratings
ModelColumbia Boiler MPH-70
Boiler Horsepower70 BHP
Net Steam Output (IBR)1,823,682 BTU/hr
Gross Output~2,338,250 BTU/hr (70 × 33,475)
Fuel Input (gas)~2,940,000 BTU/hr
Thermal Efficiency≥83%
Design Pressure15 psig (ASME Sec IV)
T_sat at 15 psig≈250°F
Return Condensate Temp180°F (default)
Fuel TypesNatural gas, LP, #2 oil
ConstructionMulti-pass horizontal firetube